Product Electromagnetic Compatibility Test - Electromagnetic Compatibility Rectification Suggestions

Product Electromagnetic Compatibility Test - Electromagnetic Compatibility Rectification Suggestions

2025.02.21 00:00:00
521

Product Electromagnetic Compatibility Test - Electromagnetic Compatibility Rectification Suggestions


1. Excessive radiation emission

The radiation interference emissions of the equipment exceed the standard in two possible ways. One is that the shielding performance of the equipment casing is not perfect; the other is that the radio frequency interference escapes through the power cord and other cables.


The judgment method is to remove unnecessary wires and power plugs, then continue the test. If there is no improvement sign, it should be suspected that the shielding performance of the equipment casing is not perfect.


If there is an improvement, it may be a problem with the cables. If for the above two possibilities, necessary measures have been taken, but still no improvement occurs, it may be a problem with the remaining cables on the equipment.


1.1 Imperfect Shielding Performance of Metal Enclosure


⑴ The gaps in the enclosure are too large, or there are problems in the assembly. Solutions:


① Remove the paint, oxide layer and surface dirt on the mating surfaces;


② Increase the number of fasteners on the mating surfaces and the flatness of the contact surfaces;


③ Use permanent seams (continuous welding);


④ Use conductive pads to improve the contact performance of the contact surfaces.


⑵ Other functional openings are too large


Handling Opinion:


① The ventilation openings are equipped with dust-proof plates, and waveguide ventilation plates are used when necessary, but the latter is costly;

  

② The display window is made of transparent material with shielding function; or it is divided into compartments and signal lines are filtered;


③ Enclosures are used for keyboards and other components, and signal lines are filtered.


⑶ The wiring inside the chassis is improperly arranged, and electromagnetic interference escapes through the gaps.


Solution: The layout of printed boards and internal wiring of the equipment that may cause radiation interference should be moved away from the gaps or functional openings, or remedial measures such as adding shielding or re-arrangement should be taken.

1.2 Non-metallic Enclosure


① Conductive coating should be applied to the enclosure, with particular attention paid to the gaps at the junctions, to ensure that there are conductive connections within the enclosure;


② Local shielding should be implemented for parts that generate electromagnetic interference and those that may cause such interference, and all wires entering or leaving the shielding body should be filtered or covered with magnetic absorption rings;


③ The layout of internal wiring and printed circuit boards should be reconsidered to minimize the loop of signals and their return lines.


1.3 Cable Issues (including problems with remaining cables on equipment)


⑴ Handling of power cables


① Install power cable filters (if already present, replace with high-performance filters). Pay special attention to the installation location (as close as possible to the power cable inlet end of the enclosure) and installation conditions, ensuring that the filter housing is well connected to the enclosure and has good grounding;


② If the frequency is not qualified and is relatively high, consider installing ferrite magnetic rings at the power cable inlet part.


⑵ Handling of signal cables


① Place ferrite magnetic rings (or ferrite magnetic clips) on the signal cables;


② Filter the signal cables (common-mode filtering); if necessary, replace connectors with filtering array boards or filtering connectors;


③ Replace with shielded cables. The shielding layer of the shielded cables should be as closely connected to the enclosure as possible, and if necessary, cover the shielding line with ferrite magnetic rings.


2. Excessive conductive emission

The equipment's conducted emission exceeds the standard, mainly due to issues with the cables. However, the excessive frequencies are usually relatively low, making the problem difficult to handle.


⑴ Handling of power cables


① Check if there are any signal cables near the power cables. There might be a situation where the conducted emission of the power cables exceeds the standard due to coupling between the signal cables and the power cables (this is more common when the超标 frequencies are in higher frequency bands). If so, either increase the distance between them or adopt shielding measures;


② Install power cable filters (if there are already filters, replace them with high-performance ones). Pay special attention to the installation location (try to place it at the power cable inlet end of the chassis) and the installation conditions. Ensure that the filter's casing is well connected to the chassis and has good grounding;


③ Even after taking measures, the equipment's conducted emission still does not meet the standard (especially if it does not meet the standard in the low-frequency band). At this point, consider inserting an inductor at the connection point of the grounding terminal of the equipment's internal circuits. Since this connection is a single-point grounding, there is no current flowing through it normally, so this inductor can be made very large without worrying about the saturation of the iron core. The reason for taking this measure is that the conducted emission test of the equipment is actually a common-mode voltage test (the emission of the power cable to the ground). There is a working current flowing through the power cable, so the filter's filtering inductance value is limited by the working current, and it cannot be made very large. The insertion loss of the filter is also limited, especially at the low-frequency end. The additional inductor in the new scheme can precisely make up for this deficiency, thereby achieving better suppression of conducted emissions.

⑵ Handling of Signal Lines


① Pay attention to whether there are any other radiating energies (such as nearby wiring and the layout of the printed circuit board) being conducted onto the signal lines. If so, either increase the distance between them, adopt shielding measures, or consider changing the internal layout of the equipment and the layout of the printed circuit board;


② Wrap ferrite magnetic rings (or ferrite magnetic clips) around the signal lines;


③ Perform common-mode filtering on the signal lines. If necessary, use filtering connectors (or filtering array boards). Pay attention to the parameters of the filter. The frequency at which the conducted interference emission exceeds the limit is lower than that of the radiated interference emission, so the component parameters used should be larger.


3. Failure to meet anti-static interference requirements

The immunity test against electrostatic discharge has two types: direct discharge and indirect discharge. Direct discharge involves the discharge gun directly discharging onto the surface of the equipment to conduct the discharge; indirect discharge involves the discharge gun discharging onto the object beside the equipment (in the test, the discharge gun discharges onto the horizontal and vertical coupling plates beside the equipment to simulate it).


3.1 Direct Discharge


Depending on the object, there may be two types of enclosures: metal and non-metal.


⑴ Non-metal Enclosure


The greatest advantage of a non-metal enclosure is that the shell is made of insulating material, and generally does not discharge electricity. However, if the layout of the equipment is too close to the gap of the enclosure, or if the insulation strength of the surface material is insufficient, it may cause the anti-static interference test of the equipment to fail.


The "avoidance" measure can be taken. For example, insulating boards can be used to strengthen the isolation at the gap part; or wedges can be used to increase the discharge path. For the parts with conductive plugs, the plugs can be made deeper and the gaps can be made narrower. In summary, through structural design methods, the discharge test of electrostatic discharge should not allow electricity to be discharged on this equipment.


⑵ Metal Enclosure


For metal enclosures, electrostatic discharge tests will definitely discharge electricity on the surface of the equipment. The problem is how to make the impact of the discharge on the normal operation of the equipment as small as possible.


Obviously, a device with a well-conductive connection of the enclosure, along with the low-impedance grounding measures of the enclosure, the electrostatic discharge current will be able to be quickly discharged on the enclosure surface, which generally will not cause interference to the equipment.


On the contrary, in the first few microseconds of the discharge, due to the rich high-frequency harmonics in the discharge current waveform, if the conductive connection of the enclosure is poor, and the low-impedance grounding consideration is insufficient, a high-frequency electromagnetic field can still be established on the surface of the enclosure, causing certain interference to the internal circuits of the equipment.


⑶ Cables and Other Parts


According to the standard, during the normal operation of the equipment, all parts that operators can touch are the parts that should undergo electrostatic discharge tests. From this perspective, in addition to the enclosure of the equipment, the display parts on the surface of the equipment, as well as power lines and I/O lines, also belong to the parts that should undergo discharge tests.


For the display screen, transparent shielding materials should be considered for protection. The key is to ensure a tight electrical contact between the shielding material and the enclosure of the equipment.


For power lines and I/O lines, measures such as shielding, common-mode filtering, and using ferrite magnetic rings (or ferrite magnetic clips, depending on the shape of the wire) can be adopted. For I/O lines, transient voltage absorption diodes can be used to absorb, and photo-isolators can be used for isolation, etc.

3.2 Indirect Discharge


Indirect discharge mainly affects the operation of equipment through the electromagnetic field generated by the discharge. Therefore, equipment with a shielding effect on the casing is definitely better than those without. Moreover, even if the casing is not shielded, it does not necessarily mean that the equipment will malfunction under the influence of external electromagnetic fields. This mainly depends on the sensitivity of the equipment's wiring and printed circuit board layout to the electromagnetic field, as well as the relative distance between the sensitive parts and the discharge board (referring to the vertical and horizontal coupling boards used in the test). 


For equipment with non-metallic casings, the purpose of shielding can also be achieved through conductive spraying on the casing.


4. Failure to meet the requirements for resisting electromagnetic field interference from radio frequency radiation


According to the standard, the test for resisting electromagnetic field interference from radio frequency radiation mainly targets the surface of the equipment. In fact, the power cord and I/O lines of the equipment are also exposed to the radio frequency radiation electromagnetic field simultaneously. Therefore, the power cord and I/O lines may also act as passive antennas, introducing interference into the equipment and causing it to malfunction.


The handling opinion for the failure of the equipment to resist electromagnetic field interference from radiation is similar to that for the equipment exceeding the emission limit of radiation interference. The difference lies in the direction of the electromagnetic field. In the former case, the external interference affects the internal circuitry operation; in the latter case, the internal interference escapes from the equipment, causing the emission limit of radiation interference to be exceeded.


5. Failure in Anti-Pulse Group Interference


From the perspective of the original intention of the pulse group test, the main purpose is to conduct common-mode interference tests. However, the waveforms of the interference pulses are extremely steep and their duration is very short, thus containing extremely rich high-frequency components. This leads to a portion of the interference escaping from the transmission cables during the transmission process. As a result, the equipment ultimately receives a combined interference of both conduction and radiation.


For pulse group interference, filtering (for power lines and signal lines) and absorption (using ferrite magnetic cores to absorb) are mainly adopted. The ferrite magnetic core absorption solution is very inexpensive and very effective. However, it is important to note the placement of the ferrite magnetic core during the test, which is the location where the ferrite magnetic core will be used in the future. Do not change it randomly, as we have repeatedly emphasized that pulse group interference is not only a conduction interference, but more importantly, it also contains radiation components. Different installation positions result in different escape situations of radiation interference, which is difficult to predict. Generally, ferrite magnetic cores are used at the source of interference and the entrance of the equipment for the most effective result.


6. Failure in the surge interference resistance test


The most distinctive feature of the lightning surge test is its extremely high energy. Therefore, the conventional filtering and absorption schemes using ordinary filters and ferrite cores are basically ineffective. Special surge absorption devices such as gas discharge tubes, voltage-sensitive resistors, silicon transient voltage absorption diodes, and semiconductor discharge tubes must be used.


There are two types of lightning surge tests: common mode and differential mode. Therefore, the selection of surge absorption devices should take into account the corresponding situation of the test. To demonstrate the effectiveness, the surge absorption devices should be used at the incoming line inlet. Due to the extremely high di/dt during the surge absorption process, there should be no signal lines or power lines passing near the devices to prevent interference from being introduced into the signal and power lines through electromagnetic coupling. In addition, the pins of the surge absorption devices should be short; the absorption capacity of the devices should match the test levels of surge voltage and current.


Finally, using a combined protection scheme will enable different protection devices to showcase their respective characteristics, thereby achieving the best protection effect.


7. The conducted interference immunity test for the interference caused by radio frequency fields failed.


From the perspective of the test method, the conducted interference immunity test caused by the induction of the radio frequency field is a common-mode test. After the aforementioned several tests (especially the electrostatic discharge, radio frequency radiation electromagnetic field, and pulse group tests), generally there should be no major problems. If there are any issues, they can mainly be resolved by strengthening filtering and improving the wiring and layout within the equipment.