A protection diode is usually chosen from a 25 °C table and then used in an enclosure that reaches 85 °C or more. Three rows of the same datasheet behave very differently across that range, and only one of them is likely to break the design.

Direct answer

Leakage moves first, by orders of magnitude. Standoff voltage barely changes because it is set by doping, not by temperature. Clamp voltage rises moderately because the junction resistance increases with temperature. Rank the three rows by how fast they move and the temperature review becomes a short checklist instead of a full re-qualification.

Leakage is the row that scales exponentially

Reverse leakage in a silicon junction roughly doubles for every 10 °C to 15 °C of junction temperature. A part specified at 1 nA and 25 °C can reach hundreds of nanoamperes at 125 °C, and that current flows through whatever impedance sits in parallel with the protected node. On a high-impedance analog input the resulting offset is visible on the ADC; on a battery-backed rail it shows up as drain over weeks. Standoff voltage, by contrast, is fixed by the doping profile and moves by a few percent over the same range.

Review itemCondition to recordWhy it matters
Leakage at 125 °CValue at the actual rail voltage, not at 0 VDrives offset and drain
Standoff voltage25 °C value plus any temperature coefficient givenSets the rail it can sit on
Clamp at rated currentPulse current, waveform and temperatureDecides survival of the load
Package thermal pathPad area and copper underneathSets how fast the die cools

Three rows, three different review methods

Leakage needs a worst-case multiplication, not a typical value: take the 25 °C maximum, apply the datasheet curve if one is given, and compare the result against the offset budget of the receiving circuit. Standoff voltage needs a margin check against the highest steady-state rail, including transients that last longer than a millisecond. Clamp voltage needs a pulse-condition check, because a value quoted at one current and one waveform does not transfer to another. Treating all three as one number is where most thermal reviews go wrong.

  • Multiply leakage, do not read it — use the curve or the temperature derating table, never the 25 °C typical.

  • Keep standoff margin at the hot rail — a rail that overshoots at start-up is the real limit.

  • Quote clamp with its current — a clamp figure without a pulse current is not a specification.

A table that survives the temperature review

The table has to separate what was measured from what was derived. Record the datasheet value, the condition it was measured at, the derating applied and the resulting number used in the design. When a reviewer asks why a 5 V rail uses a part with 6.8 V standoff, the answer should be visible in the same row, not reconstructed from memory.

FieldHow to write itWhy it cannot be skipped
Source valueDatasheet figure with page and revisionTraceability for later questions
ConditionVoltage, current, waveform, temperatureNumbers without conditions do not transfer
DeratingFactor applied and its basisMakes the margin auditable
ResultValue used in the designOne number, one owner

Order of checks at elevated temperature

  1. Start with leakage at the highest rail voltage and the highest ambient.

  2. Check standoff margin against the worst steady-state rail, including start-up overshoot.

  3. Re-read clamp at the pulse current the load will actually see.

  4. Confirm the thermal path from die to copper before accepting the result.

FAQ

Is a leakage figure at 0 V useful?

Only for comparing parts. At 0 V there is almost no field across the junction, so the number says little about behaviour on a live rail. Ask for leakage at the working voltage, or use the curve.

Does clamp voltage really rise with temperature?

Yes, moderately, because the series resistance of the junction and its metal path increases. The rise is smaller than the leakage change but large enough to matter when the margin to the load absolute maximum is thin.

Sources

Source check date: 2026-10-28. Leakage scales with temperature far faster than standoff voltage; review them separately.