What UWB Ranging Modules Need From an ESD Diode Beyond Clamp Voltage

What UWB Ranging Modules Need From an ESD Diode Beyond Clamp Voltage

2026.10.29 00:00:00
28

A UWB module that passes ESD testing and then reports ranging errors of tens of centimetres is a familiar outcome. The protection diode did its job on the pulse, but it also sits on the antenna feed and changes the delay the module measures.

Direct answer

Clamp voltage is only the first screen. On a UWB feed the diode adds capacitance in parallel with the antenna and the front end, which shifts the matching network and adds group delay that varies with frequency. A part with a low clamp and a fraction of a picofarad behaves very differently from one with the same clamp and several picofarads, and the difference shows up as ranging bias rather than as a failure.

The feed sees capacitance, not clamp voltage

UWB channels sit between roughly 3.5 GHz and 9 GHz depending on the band group in use. At those frequencies a diode placed on the feed is a capacitor with a lossy junction, and its value at the band centre is what the matching network sees. A part specified at one frequency can present a different capacitance at another, so a number taken from a summary table is not enough to predict the shift. The visible effect is a small impedance mismatch, a few tenths of a decibel of loss, and a phase response that is no longer flat across the band.A ferrite bead or a long stub next to the diode can dominate the response far more than the diode itself, which is why the fixture has to match the final layout.

Review itemCondition to recordWhy it matters
Band groupChannel centre and occupied bandwidthSets the frequency where Cj matters
Capacitance at bandValue at the band centre, not at 1 MHzDrives the matching shift
Group delay rippleVariation across the occupied bandTurns into ranging bias
Feed impedanceMeasured before and after fittingConfirms the shift is real

Three things to measure before choosing a part

First, measure the feed impedance with the diode removed and again with it fitted, on the same fixture. Second, measure group delay across the occupied band rather than at a single point, because a flat loss still leaves a slope that the ranging algorithm reads as distance. Third, check the capacitance at the band centre rather than at the frequency printed in the summary table, since the two can differ by a large factor on small packages. If the module already meets its accuracy target without a feed diode, a diode on the enclosure side of the matching network is often the better place for it.Two candidate parts should be compared on the same board with the same matching values; comparing datasheet numbers taken on different test boards answers a different question altogether.

  • Measure at the band, not at 1 MHz — the summary value rarely describes the feed.

  • Look at delay slope, not only loss — a flat loss is harmless, a slope is not.

  • Consider the enclosure side — protection before the matching network costs less accuracy.

What to put in the ranging report

A ranging report that lists only pass or fail at a given test level cannot explain a bias. Add the band group, the capacitance at the band centre, the group delay variation, the measured bias before and after fitting the part, and the temperature at which each number was taken. With those five fields a bias of twenty centimetres can be traced to a component change instead of being argued about, and a part substitution can be judged before it reaches a customer.Keep the fixture photograph with the numbers, because a bias measured on a different board revision is not comparable and will be argued about later.

ItemHow to write itWhy it matters
BandGroup, channel, occupied bandwidthFixes the frequency of interest
CapacitanceValue and frequency of measurementDrives matching and delay
DelayVariation across the bandConverts directly into bias
BiasMean and spread, before and afterShows the size of the effect
TemperatureAmbient at each measurementCapacitance and loss drift

Order of work when ranging bias appears

  1. Record the bias with the diode removed to establish a baseline.

  2. Fit the candidate part and repeat the same measurement.

  3. Measure group delay across the band, not at the centre only.

  4. Keep the part only if bias stays inside the accuracy budget.

FAQ

Does a lower clamp voltage always improve ranging accuracy?

No. Clamp voltage describes a transient event, while accuracy depends on the small-signal behaviour at the band centre. A part can clamp better and still add more delay, in which case accuracy gets worse.In practice the accuracy budget is set by the antenna and the clock, and the diode only spends part of it; a part that uses most of the budget fails later for an unrelated reason.

Can the diode be moved away from the feed to reduce the effect?

Moving it behind the matching network reduces the shift seen by the antenna, but it also reduces the protection of the front end. The trade is decided by which side is more exposed to discharge in the actual enclosure.On modules with an external connector the feed is the most exposed point, so the trade usually favours protection there and a tighter matching tolerance elsewhere.

Sources

Source check date: 2026-10-29. Clamp voltage describes a transient; accuracy depends on small-signal behaviour at the band.