On a Type-C Receptacle, Why CC and SBU Cannot Share One Array
A 24-pin Type-C receptacle carries four voltage domains in one shell: VBUS up to 20 V under PD, CC at up to 5.5 V, SBU at 3.3 V, and the USB 2.0 pair at 3.3 V. One four-channel array looks like a tidy fit for CC1, CC2, SBU1 and SBU2. In a ±8 kV contact test on the shell it is also the arrangement that fails first.
Direct answer
Use two separate parts: an ESD5D150TA from CC1 and CC2 to ground, and an ESD3V3D500TA on SBU1 and SBU2. A shared array ties all four channels to one common pin, and that pin lifts the CC clamp whenever SBU takes the strike. Keep both parts within 3 mm of the receptacle.
Four pins, two voltage domains
| Pin / stage | Signal | Normal level | Diode needed | Why |
|---|---|---|---|---|
| A5 / B5 | CC1 / CC2 | 0–5.5 V, Rp 56 kΩ or Rd 5.1 kΩ | Yes, 5 V dual part | Carries PD negotiation, a shifted level breaks the contract |
| A8 / B8 | SBU1 / SBU2 | 0–3.3 V, alternate mode | Yes, 3.3 V dual part | Sideband pair, low current, high impedance |
| A4 / B4 / A9 / B9 | VBUS | 5–20 V under PD | Yes, 24 V class | The pin the plug reaches first |
| A6 / A7 | D+ / D- | 0–3.3 V | Yes, 5 V low-cap | USB 2.0 pair at 480 Mbps |
| A2–A11 | TX / RX super-speed pairs | 0–3.3 V differential | 0.3 pF class | 10 Gbps lanes, capacitance budget is the limit |
| Shell | Receptacle shell | 0 V | Single-point bond | A floating shell couples into CC |
The common pin, not the clamp voltage
A four-channel array has one ground pin shared by all four channels. At the edge rate of an IEC 61000-4-2 strike that pin is an inductor of about 1.5 nH, and 30 A changing in 1 ns develops roughly 30 V across it. When SBU1 conducts, the common pin rises, and the CC channels see their reference move with it. CC is a resistor divider: Rd is 5.1 kΩ on the device side, Rp is 56 kΩ on the source side, and the PD contract is agreed on a few hundred millivolts of margin. A 1 V shift on the CC reference is enough to renegotiate, and the visible symptom is a charger that drops from 20 V to 5 V and then climbs back. Two separate parts keep the two domains apart, and the CC pair keeps its own short return.
Placement and the return path
Place the CC part within 3 mm of pins A5 and B5, on the same side as the receptacle, with 0.2 mm traces and no stubs. Place the SBU part within 3 mm of A8 and B8. Both parts get two vias each to the ground pour under the receptacle, and that pour connects to the board ground at one point. Do not route CC under the shell: the shell carries the strike current, and a CC trace running beneath it couples the edge straight into the divider. Keep the CC1 and CC2 traces the same length, because a length mismatch turns the common-mode strike into a differential step on the pair. Bond the shell at one point only; two bonds create a loop that passes under the super-speed pairs.
Test levels and pass criteria
Contact discharge at ±8 kV on the shell, on the four VBUS pins, on CC1 and on SBU1, ten strikes per polarity, with a PD source and a sink both powered. Air discharge at ±15 kV into the gap around the receptacle. Judge on the contract, not on the picture: the sink must hold 20 V and 3 A through the whole sequence, VBUS must not droop below 4.5 V during a strike, and the CC level must return within 100 mV of its pre-test value. A renegotiation that recovers in two seconds still counts as a fail, because the user sees a charging pause. Repeat with a captive cable and with a separate cable, since the cable shield changes where the current enters.
FAQ
Can a 24 V part cover CC as well as VBUS?
It can survive, but its clamp is set for a 20 V rail, so the CC divider sees a much higher residual than a 5 V part leaves. PD negotiation runs on a few hundred millivolts, and that residual is enough to shift it.
Why not put one part across CC1 and CC2?
A part across the pair only clamps the difference between the two pins. The strike is common mode against the shell, so the current still has to find a path through the PD controller. Two parts to ground give it that path.
Sources
Source check date: 2026-10-31. The array does not fail on clamp voltage; it fails on the pin the four channels share.
Related News
2025.02.21
Several methods for rectifying electromagnetic compatibility issues
2025.09.03
What are the advantages of bidirectional TVS diodes? How to distinguish the polarity of TVS Diodes -ASIM
2026.07.13
How do I select a 5V low-capacitance ESD diode model?
2026.07.23
How to Select Low-Capacitance ESD Protection for MIPI D-PHY Interfaces: Key Design Considerations for Camera and Display Links
2026.08.05
How to Read TVS Diode Reverse Leakage Current (IR): Temperature, VRWM, and Standby Power
2026.08.07
Single-Channel ESD Diodes vs ESD Arrays: How to Choose