RJ45 Isolation Transformer: Placing the TVS on the Line or PHY Side
An RJ45 port is the one interface where the discharge arrives from a cable that may be tens of metres long and referenced to a different earth. The isolation transformer separates the cable side from the PHY side, and in doing so it splits the current into two legs that no longer share a return. Protection has to be considered per leg.
The transformer splits the two legs
On the cable side the pair carries whatever common-mode voltage exists between the two ends of the link. On the PHY side the pair is referenced to the local ground. The transformer passes the differential signal and blocks the common-mode difference, at least at low frequency.
At the edge rates involved in an 8 kV contact discharge the inter-winding capacitance is a low impedance, so a fast common-mode step crosses the barrier as a displacement current rather than being blocked. That current arrives on the PHY side with no return path defined yet.
Line side: the cable common mode
A TVS on the line side sees the full cable common mode, which for a long run can be tens of volts of standing offset before any discharge occurs. The standoff has to clear that offset, which is why line-side parts are usually rated well above the 5 V that a logic-level part would use.
The line-side part also has to survive the surge waveform, not just the ESD waveform. A 1.2/50 µs combination wave delivers far more energy than an 8 kV contact discharge, and a part selected only on ESD peak current will fail on energy.
PHY side: the transceiver limit
The PHY absolute maximum is typically 3.6 V on the media-side pins. A line-side clamp at 30 V does nothing for that pin; what protects it is either the transformer insulation plus the centre-tap termination, or a second device on the PHY side.
A PHY-side device needs a low clamp and low capacitance, because it sits directly across the differential pair that carries 1000BASE-T. Capacitance here is less critical than on USB or HDMI, but a few picofarads still matter at 125 MBd with echo cancellation.
| Position | Sees | Standoff driver | Clamp target |
|---|---|---|---|
| Line side, pair to chassis | Cable common mode plus surge | Cable standing offset | Below transformer insulation |
| PHY side, pair to ground | Residual through the barrier | 3.3 V rail | Below 3.6 V at the test current |
| Centre tap to ground | Common-mode return | Rail plus offset | Shared with the pair devices |
What the centre-tap termination does to the return
Each winding centre tap is terminated to ground through a resistor and a capacitor, often 75 Ω and 1000 pF. This network is the intended return for common-mode current and it also sets the impedance that the common-mode choke works against.
If the capacitor is a small 0402 with a long trace to the ground via, its impedance at 100 MHz is dominated by the trace, not the part. The common-mode current then develops a voltage across that trace and appears as a differential offset at the PHY.
One part per side, not one part total
A common mistake is to fit a single array on the PHY side and treat the port as protected. That covers the transceiver but leaves the line side with no clamp, so the surge energy is absorbed by the transformer insulation and the centre-tap capacitor.
The other mistake is the reverse: a large line-side part with nothing on the PHY side. The transformer blocks the slow component, the fast edge crosses as displacement current, and the PHY takes a residual that no line-side clamp can influence.
Retest with the cable plugged in
Discharge the shell with the cable disconnected, then repeat with a two-metre cable attached and the far end terminated. The second case is the one that matters: the cable carries the current to the far end and back, and the loop includes the remote chassis.
Acceptance: link stays up through all strikes, negotiation time returns to the baseline within one attempt, error counters show no step, and the common-mode voltage measured at the centre tap stays below the capacitor rating.
FAQ
Does an ESD diode on the line side make a surge protector unnecessary?
Not usually. The energy in a combination wave is orders of magnitude above an 8 kV contact discharge, so the line-side device is selected on energy first and clamp second.
Can the centre-tap capacitor replace a PHY-side TVS?
It provides a return path but no clamp. The capacitor lowers the impedance the common-mode current sees; it does not limit the voltage at the PHY pin once the transformer capacitance has passed the edge.
Sources
Surge and ESD numbers in this note come from the standard waveforms named in each section. Transformer insulation ratings vary by part; check the datasheet for the model you use rather than assuming a class.
Related News
2024.10.12
EMC testing Contents and Current Situation of Automotive Electronic products
2024.12.18
Test standards for automotive electronic load rejection shock tests
2026.06.11
How Chinese ESD Manufacturers Match Global Standards: ASIM Technical Analysis
2026.07.24
How to Select a TVS Diode for the Power Input: A Complete Process from Operating Voltage to Clamping Voltage
2026.07.28
Why does adding a filter fail to resolve EMC issues? First, determine whether the noise is common-mode or differential-mode.
2026.08.07
How to Interpret TVS Diode VBR Tolerance and Temperature Shift