TVS Derating in a Small Package: Where the Thermal Margin Goes

TVS Derating in a Small Package: Where the Thermal Margin Goes

2026.10.27 00:00:00
42

Peak pulse power on the front page of a TVS datasheet is measured with one waveform, at one ambient temperature, for one pulse. Move the same die into a smaller package and the derating curve steepens, even though the headline number does not change.

Direct answer

Separate three numbers that are usually printed together: peak pulse power for a stated waveform, thermal resistance from junction to ambient, and the derating curve that ties them to temperature and pulse repetition. In a small package the junction-to-ambient path dominates, so the usable power falls faster with ambient temperature and with repeated pulses.

The headline number hides two conditions

A 1500 W rating is normally quoted for a 10/1000 microsecond exponential waveform at 25 °C with a single non-repetitive pulse. An 8/20 microsecond waveform carries far more peak current for the same energy, so the two numbers are not interchangeable. On top of the waveform, the rating assumes an ideal heat path: in a DFN or SMA package the copper area under the pad is part of that path, and a two-layer board with a small pad is not the board the curve was drawn on.

Review itemCondition to recordWhy it matters
Waveform10/1000 microsecond or 8/20 microsecond, single pulseSame energy means different peak current
Ambient temperature25 °C, 85 °C or the actual enclosure temperatureDerating slope applies from the reference point
MountingPad area and copper thicknessJunction-to-ambient resistance depends on it
RepetitionSingle pulse or repeated at a stated intervalAverage power, not peak power, heats the die

Three places the margin disappears

Margin is not lost in one step. It is lost when the waveform is swapped, when the ambient is taken from the room instead of the enclosure, and when a single-pulse rating is applied to a port that sees repeated transients. Each substitution looks small on its own and compounds in the same direction.

  • Waveform swap:a 1500 W part at 10/1000 microsecond is not a 1500 W part at 8/20 microsecond; compare peak current at the actual waveform.

  • Ambient swap:use the temperature inside the enclosure, measured after warm-up, not the lab bench temperature.

  • Repetition swap:average power over the repetition period sets the steady-state junction temperature, and that is what the derating curve limits.

The four rows that keep the derating honest

A derating sheet is only useful if the next engineer can recompute the junction temperature without asking which assumptions were used. Four rows cover it: waveform and pulse count, ambient and its measurement point, thermal path including pad area, and the resulting junction temperature against the rated maximum.

RecordSuggested entryWhy it cannot be omitted
WaveformShape, pulse width, source impedanceSets peak current for a given energy
AmbientMeasured enclosure temperature after warm-upThe derating curve starts from this point
Thermal pathPackage, pad area, copper layersJunction-to-ambient resistance is layout dependent
Junction temperatureCalculated value versus rated maximumThe only number that decides pass or fail

Check order for a small-package TVS

  1. Convert the field transient into a waveform and pulse count before reading any rating.

  2. Read peak pulse current at that waveform, not peak power at another one.

  3. Apply the derating curve from the measured enclosure ambient, then add the pad-area correction.

  4. Compute junction temperature for the repetition rate and compare with the rated maximum.

FAQ

Is a higher peak pulse power rating always better?

Only at the same waveform and the same ambient. A higher number measured at a longer pulse can still mean less peak current at the short waveform the port actually sees.

Does a larger pad really change the rating?

It changes junction-to-ambient thermal resistance, which is what the derating curve is drawn against. The die is identical; the usable power is not.

Sources

Source check date: 2026-10-27. Thermal resistance values are package and layout specific; use the value from the datasheet that matches the actual copper area.